A category C blast load, 4psi 30psi/ms is detonated.

Untreated Window:

Shockwave is breaking untreated window. Glass fragments are blown into building, creating and extremely deadly hazard.

Treated Window:

Shockwave hitting windows that are treated with SafteyShield 800 and two-sided Frameguard attachment system. Adequately performs to GSA

Test Data

Impact

ANSI Z-97 Unlimited
CPSC Category II

Hurricane

ASTM E-1996 Large Missile Impact Category B
Cycling +/- 100 psf
Tested on 3/16" tempered patio door with silicone wet glaze attachment at American Test Labs of South Florida, Ft. Lauderdale

Blast Mitigation

Attachment Syst. GSA Performance Condition
4 Side FrameGuard 2
2 Side FrameGuard 3B
4 Side Wet Glaze 3B
Subjected to GSA category C blast loads, 4psi 30psi/ms. Tested at Defense Research Establishments Suffield (DRES), Ralston, Alberta by EQE International

Accelerated Weathering

Miami/Dade Criteria, 4500 hours
Xenon Arch Per: ASTM G56-95 PASS

Puncture Strength

ASTM D-4830-88 129 lbs

Tear Strength

ASTM D-1004 > 18 lbf

Surface Burn Characteristics -
ASTM E-84

Flame Spread Index "A" Rating
Smoke Developed Index "A" Rating

Title of Test

Ext. Uniform Structural Load 202 mph

Optical Properties:

Total Solar Energy

Transmitted 78%
Reflected 10%
Absorbed 12%

Visible Light

Transmitted 84%
Reflected 10%

"U" Factor

Median 1.08
Design 1.12
Ultraviolet Light Rejected 99%
Shading Coefficient 93
Total Solar Energy Rejected 19%

Physical Properties

Film Thickness 0.008"
Structure Multiply Laminate
Tensile Strength 25,000 PSI
Break Strength 200 lbs./in
Adhesive Type Acrylic PSA
Peel Strength 5 to 6 lbs/in

Abbreviation Table
ANSI - American National Standards Institute
ASTM - American Society for Testing and Materials
BS - British Standards
CPSC - Consumer Product Safety Commission
GSA - General Services Administration
LBF - Pounds force
MIL - Thickness measurement
PSI - Pounds per square inch